Calculate orifice diameter, liquid flow rate, or pressure drop from flow, fluid density, and discharge coefficient with metric and imperial units.

For incompressible liquid with negligible upstream approach velocity.

Use the positive pressure difference across the opening.

Water estimate is near 20ยฐC; other presets vary with composition and temperature.

Use a tested value for your opening and operating conditions; the estimate is not a universal constant.

Options


Related Calculators

Calculator Functions

FunctionWhat it doesWhat it requires
Orifice diameterSizes a round orifice to pass a set liquid flow at a set pressure dropRequires the liquid flow rate, the pressure drop, the liquid density and the discharge coefficient
Liquid flow rateEstimates the flow a round orifice of known size passes at a set pressure dropRequires the orifice diameter, the pressure drop, the liquid density and the discharge coefficient
Pressure dropFinds the pressure difference needed to push a set flow through an orifice of known sizeRequires the orifice diameter, the liquid flow rate, the liquid density and the discharge coefficient

Flow is entered in L/min, mยณ/h, US gpm or mยณ/s, pressure in kPa, bar, psi or Pa, and diameter in mm or inches. The density comes from a preset (water 998 kg/mยณ, light oil 850, heavy oil 900, ethanol 789) or a custom value, and the discharge coefficient starts at 0.62. Every result lists the diameter, opening area, flow, pressure drop, mean velocity through the opening and mass flow together.

Orifice Size Formulas

Q = Cd ร— A ร— โˆš(2ฮ”P รท ฯ) [1]
QFlow rate through the orifice (mยณ/s)
CdDischarge coefficient of the opening, a number of 1 or less
AArea of the opening (mยฒ)
ฮ”PPressure drop across the orifice (Pa)
ฯDensity of the liquid (kg/mยณ)

The U.S. Bureau of Reclamation writes the orifice equation with a differential head, Q = Cd ร— A ร— โˆš(2gฮ”h), and notes that 2gฮ”h becomes 2ฮ”P รท ฯ when the difference is measured as a pressure [1]. The term โˆš(2ฮ”P รท ฯ) is the ideal jet velocity, and Cd scales it down for the narrowing of the jet and for friction.

Orifice diameter

A = Q รท [Cd ร— โˆš(2ฮ”P รท ฯ)]
d = 2 ร— โˆš(A รท ฯ€)

The main formula is rearranged for the area, and the area is turned into the diameter of a round opening. For 100 L/min of water (0.001667 mยณ/s) at a 100 kPa drop with Cd = 0.62, the ideal velocity is โˆš(200,000 รท 998) = 14.16 m/s, the area is 0.001667 รท (0.62 ร— 14.16) = 189.9 mmยฒ, and the diameter is 15.55 mm. The same duty in light oil at 850 kg/mยณ needs 14.94 mm, because a lighter liquid moves faster under the same pressure.

Liquid flow rate

The main formula applies directly, with A = ฯ€ ร— (d รท 2)ยฒ. A 10 mm orifice has an area of 78.54 mmยฒ and passes 0.62 ร— 0.00007854 ร— 14.16 = 0.000689 mยณ/s of water at 100 kPa, which is 41.36 L/min or 10.93 US gpm.

Pressure drop

ฮ”P = (ฯ รท 2) ร—
[Q รท (Cd ร— A)]ยฒ

Pushing 50 L/min of water through the 10 mm orifice takes 146.1 kPa (21.2 psi) at Cd = 0.62. The pressure drop rises with the square of the flow, and it is sensitive to the coefficient: at Cd = 0.8 the same flow takes 87.8 kPa.

Discharge coefficient

The starting value of 0.62 suits a sharp-edged opening. The jet leaving a sharp-edged orifice narrows to about six-tenths of the opening area, which gives a contraction coefficient of about 0.61 [2]. For an orifice plate inside a pipe the coefficient ranges from 0.60 to 0.80 and changes with the ratio of orifice diameter to pipe diameter [3]. Coefficients are found by calibration and are not constant across all flows [3], so a tested value for the actual opening is the one to enter.

Limits of This Estimate

  • The formula is for liquids that do not compress. It does not apply to gas or steam, such as natural gas or propane burner orifices, or to choked, flashing or cavitating flow.
  • It assumes the liquid upstream is moving slowly compared with the jet. An orifice plate that fills much of a pipe needs a velocity-of-approach correction, and a metering plate is sized with a coefficient that depends on the diameter ratio, the Reynolds number and the pressure tap positions [1]. The calculator has no pipe diameter input and is not an ISO 5167 meter design.
  • Installation matters as much as the arithmetic. Poor installation of an orifice plate can cause an error of as much as 20 percent [1].
  • The density presets are approximate. Water is taken near 20 ยฐC, and oils and ethanol vary with composition and temperature.

Sources

  1. U.S. Bureau of Reclamation, Water Measurement Manual, Chapter 14, Section 3: orifice flow equation, the pressure form of the head term, what the coefficient depends on, and installation error
  2. U.S. Bureau of Reclamation, Water Measurement Manual, Chapter 2, Section 8: jet contraction and the 0.61 coefficient for a sharp-edged orifice