Measure delivered water flow from a bucket fill test or conventional pressure-tank refill test. These short tests do not establish sustained well yield or water quality.
- All Construction Calculators
- All Rate Calculators
- Active Wet Well Volume Calculator
- Water Flow Rate Calculator
- Drain Flow Rate Calculator
Well Water Flow Rate Formula
The following two example problems outline the steps and information needed to calculate the Well Water Flow Rate.
- Where WWFR is the measured delivery or average pump refill rate (US gallons per minute)
- G is the collected volume for a bucket test, or usable pressure-tank drawdown volume, in US gallons
- T is bucket fill time, or pump-on refill time with all outlets closed, in seconds. Do not include pump-off drawdown time.
Divide measured US gallons by the corresponding test time in seconds, then multiply by 60. For the pressure-tank method, use usable drawdown between matching pressure limits and time only the pump-on refill with outlets closed; nominal tank capacity and the entire off-on-off cycle are unsuitable.
How to Calculate Well Water Flow Rate?
The following example problems outline how to calculate Well Water Flow Rate.
Example Problem #1:
- First, determine the gallons drawn.
- The gallons drawn is given as 3.
- Next, determine the pump-on refill time with all outlets closed.
- The pump-on refill time is provided as 20 seconds.
- Finally, calculate the Well Water Flow Rate using the equation above:
WWFR = G / T * 60
The values provided above are inserted into the equation below and computed.
WWFR = 3 / 20 * 60 = 9 (GPM)
Example Problem #2:
For this problem, the variables required are provided below:
gallons drawn = 4
pump-on refill time with outlets closed = 30 seconds
Using 4 US gallons and 30 seconds gives 8 US gallons per minute.
WWFR = G / T * 60 = ?