Calculate the truck blower size for a dry bulk trailer: the CFM a hose needs, the blower speed and horsepower at your pressure, and the engine RPM.
- All Construction Calculators
- Air Blower Capacity Calculator
- cfm to rpm Converter
- Compressed Air Velocity Calculator
- Hopper Design Calculator
- Blower RPM Calculator
Calculator Functions
The calculator sizes a positive displacement truck blower for unloading a dry bulk trailer. It gives the airflow the discharge line needs in CFM, the blower speed that delivers it at your operating pressure, the horsepower the blower takes, and the engine speed through a PTO.
| Function | Use it when | You enter |
|---|---|---|
| Size a truck blower | You are choosing a blower, a blower speed or a PTO ratio for a pneumatic trailer | Hose size, the air the product needs, operating pressure and the blower |
The air can be a cement preset, your own air velocity, or a CFM figure you already have. The pressure starts at 15 psi, a common operating pressure for dry bulk trailers [3]. Four blowers are preset from their published performance charts [2], and Custom takes any other blower’s displacement and slip. Optional settings add the PTO ratio, which gives the engine speed, and the altitude, which lowers the preset blowers’ pressure limit.
Truck Blower Sizing Formulas
| Q | Airflow the blower must deliver (CFM) |
| v | Air velocity in the discharge line (ft/min) |
| A | Inside area of the hose or pipe (ft²), π × d² ÷ 4 with the diameter d in feet |
| N | Blower speed (rpm) |
| S | Slip: air that leaks back through the blower’s clearances (CFM) |
| D | Blower displacement (ft³ per revolution) |
A 4 in line has an area of 0.0873 ft², so 3,400 ft/min needs 3,400 × 0.0873 = 297 CFM. The cement presets of 2,900, 3,400 and 4,000 ft/min are the low end, middle and high end of one blower maker’s ideal cement range of 250 to 348 CFM through a 4 in pipe [2]. More air is not better: too much air lengthens the unload [4].
Slip
k is the blower’s slip at 1 psi in CFM, and P is the operating pressure in psi. Slip grows with the square root of the pressure and does not depend on speed, so a blower turning slowly loses a larger share of its air. At 15 psi the P858e slips 28 × √15 = 108 CFM, and it must turn (297 + 108) ÷ 0.35 = 1,158 rpm to deliver 297 CFM.
| Blower | D (ft³/rev) | k (CFM) | Speed (rpm) | Max psi |
|---|---|---|---|---|
| Paragon P858e | 0.350 | 28 | 600 to 3,000 | 20 |
| Paragon P657 | 0.358 | 32.3 | 1,000 to 2,000 | 18 |
| Paragon P858 | 0.3475 | 42 | 1,800 to 3,000 | 20 |
| Paragon P1057 | 0.460 | 56.4 | 1,700 to 3,000 | 19 |
D and k for each preset reproduce the maker’s chart airflow within about 1% [2]. The P657 limit is its continuous rating. For another blower, D is the change in CFM divided by the change in rpm between two rows of its chart, and k is D × rpm minus the chart CFM, divided by the square root of that column’s pressure.
Blower horsepower
This is the power needed to compress the air. For the example, 0.00436 × 0.35 × 1,158 × 15 = 26.5 hp. The presets’ charts list brake horsepower within about 5% of this figure [2]. The PTO and the engine must supply it with margin, so do not undersize the PTO [4].
Engine speed and PTO ratio
E is the engine speed and R is the PTO ratio, the blower turns per engine turn. A blower that needs 1,800 rpm with a 1.8 ratio runs at 1,000 engine rpm. Pick the ratio so the engine stays at a moderate speed while the blower stays inside its speed range [4].
Limits of This Estimate
- The air a product needs depends on the product, the line length and the bends. Only the cement presets come from a published range, so enter a velocity or CFM from your blower or trailer supplier for other products. These estimates are based on the best available data and estimations.
- The calculator warns when the speed falls outside the blower’s range. Running slower than the minimum raises the discharge temperature because slip takes a larger share of the air [4].
- The preset blowers lose 1 psi of maximum pressure for every 2,000 ft of altitude [3]. Custom blowers have no limits here, so check the maker’s chart.
- The result does not check PTO torque, driveshaft angle or the relief valve setting. Have the PTO specified by its maker or a distributor [4].
Sources
- pdblowers, Positive Displacement Blower Calculations: inlet volume from displacement, speed and slip, slip correction with pressure, and gas horsepower
- Paragon, Dry Bulk Solutions product portfolio: performance charts, speed ranges and pressure ratings of the P657, P858e, P858 and P1057, and the cement airflow range for a 4 in pipe
- Paragon, P858 and P1057 Operation Manual: 15 psi trailer operating pressure and the altitude pressure reduction
- Gardner Denver, Truck Blower Guide: sizing steps, effect of too much air and of slow speeds, and PTO selection
- Chemical Engineering, Moving Air in Pneumatic Conveying Systems: airflow as conveying velocity times pipe area